628. ACI 318M Reinforcement Protection Details – Free CAD Template Download
Advertisements

This CAD drawing illustrates concrete cover requirements for reinforcement based on ACI 318M-05 Chapter 7.7. It includes detailed sections for foundations, ground beams, columns, beams, ground slabs, floor slabs, and walls. Each element is clearly labeled with minimum cover thickness (e.g., 40mm indoors, 50mm for wet conditions), ensuring durability and compliance with structural standards. The notes emphasize minimum protection in seawater and oily water environments. This template is essential for engineers and drafters working on reinforced concrete projects needing precise reinforcement protection detailing.
628. ACI 318M Reinforcement Protection Details – Free CAD Template Download
You can also download the CAD Structure Details library here.
- File format: .DWG
- Size: 60 KB
- Source: Collect
- AutoCAD platform 2018 and later versions. For downloading files there is no need to go through the registration process